Product Characteristic High Efficiency/Energy Saving Low self-Consumption below 1.2A.It can reach zero at energy saving mode. Make sure the load capacity is above 200W.or the inverter can not be restarted automatically Leading energy saving technology With the AVR function.AC voltage fluctuated is within +-5% Pure sine wave Extreme overload capacity and super load capacity Working Appliance:Air-conditioners.refrigerators.water pumps.TV.Light.fans and other household appliances and office appliances etc. Durable. LF transformer technology design.it is suitable for the poor working conditions or where the grid power is not stable LED display LCD display optional DC reverse polarity protection
- Product features
- Specifications
- Download
PerformanceCharacteristic
CPU Technology control
Big Charging current. up to 70Amp.
Intelligent LED/LCD display:Grid powe.battery.ACoutput.Fault.Saving.Low voltage.Charging.
Charging curren.Battery capacity.
Intelligent battery management for maximumbattery life
Automatically switch between the grid andinverter mode
Transfer time is below 4 ms if the gridpower are cutted off
220V/110V AC 50/60Hz is optional
It can work with the generator
Intelligent fan control mode.The fan workat Temperature ≥30℃.the inverter will protect by itselfat temperature ≥100℃
LCD Display Data
Input/Output voltage | Output Power | Battery Voltage | Charge current | Input Frequency | Charge current setting |
Language Version:Chinese/English/French/Russian | Charging voltage setting | Battery Capacity setting | Battery type setting | Solar Prior Grid prior setting | Energy saving |
CommunicationData
Current | Rated power of load | Input/output voltage | Frequency |
Battery capacity | Temperature | Remote control operation | Record of history data |
TechnicalData POWER SUN
AC output Load | VMI-D 3000W | VMI-D 4000W | VMI-D 5000W |
Nominal AC voltage Optional 220V/120V | 220V/200-240V 120V/105V-132V | 220V/200-240V 120V/105V-132V | 220V/200-240V 120V/105V-132V |
Nominal AC frequency | 50Hz/60Hz | 50Hz/60Hz | 50Hz/60Hz |
Continuous AC power for 3 hours 25℃ | 2700W | 3600W | 4500W |
Continuous AC power 25℃ | 2400W | 3200W | 4000W |
Nominal AC current/ Max.AC current(peak) | 10.91A/32.73A 1ms 20.0A/60.0A 1ms | 14.55A/43.63A 1ms 26.66A/80.0A 1ms | 18.19A/54.55A 1ms 33.33A/99.99A 1ms |
THD output voltage | ≤3% | ≤3% | ≤3% |
Power Factor | 0.8 | 0.8 | 0.8 |
AC input(generator or grid) |
|
|
|
AC input voltage/range | 220V/165-270V 120V/105V-132V | 220V/165-270V 120V/105V-132V | 220V/165-270V 120V/105V-132V |
AC input frequency | 50Hz/60Hz | 50Hz/60Hz | 50Hz/60Hz |
Battery DC input |
|
|
|
Battery voltage/range Optional | 12V/10-16V 24V/20-32V 48V/40-64V | 24V/20-32V 48V/40-64V | 24V/20-32V 48V/40-64V |
Max.battery charging current/continuous charging current at 25℃ | 30A/10-30A/50A | 30A/10-30A/50A | 30A/10-30A/50 |
Battery type/Battery Capacity | Lead acid 100-1000Ah | Lead acid 100-1000Ah | Lead acid 100-1000Ah |
Charge control mode | 3 stage | 3 stage | 3 stage |
Efficiency/Self-consumption |
|
|
|
Max.efficiency | >85% | >85% | >85% |
Self-consumption with no load | 30W | 30W | 30W |
Self-consumption with no load /standby/for LCD type only | 5W | 5W | 6W |
Full intellective protection | Over voltage/over charge/AC short circuit/overload/battery discharge voltage/battery over voltage/overtemperature/over current/overheat protection/ dc polarity label | ||
Transfer time | ≤ 4ms | ||
Dimenstion(L×W×H) | 400×215×355 | 400×215×355 | 400×215×355 |
Net Weight | 29 | 32 | 36 |
Operating temperature range | 20℃ ~ 45℃ | 20℃ ~ 40℃ | 20℃ ~ 45℃ |
Degree of protection according to IEC60529 | IP20 | IP20 | IP20 |
Noise emission typical | ≤30dB (1M) | ≤30dB (1M) | ≤30dB (1M) |
Permissible value for relative humidity | 0% ~ 95% | 0% ~ 95% | 0% ~ 95% |
Accessories |
|
|
|
DC terminal | Anderson connector | Anderson connector | Anderson connector |
AC terminal | Europe terminal | Europe terminal | Europe terminal |
Warranty | 2year | 2year | 2year |
Certificate | CE/ISO9001 | CE/ISO9001 | CE/ISO9001 |
Instruction Manual | yes | yes | yes |
Optional Function |
|
|
|
Battery Cable | Optional | Optional | Optional |
Interface USB/RS232 | Optional | Optional | Optional |
SNMP Card | Optional | Optional | Optional |
Software CD | Optional | Optional | Optional |
Internet monitor | Optional | Optional | Optional |
Remoted control | Optional | Optional | Optional |
DC reverse polarity protection | Optional | Optional | Optional |
Automatically restart after cut off | Optional | Optional | Optional |
Split phase 220V/110V+-5%:output | Optional | Optional | Optional |
Alarm at inverter mode/silence | Optional | Optional | Optional |